| Sign In | Join Free | My lightneasy.org | 
 | 
Brand Name : Zhenglan Cable
Model Number : ACSR Bare Conductor(Area AL:200mm2 Steel:32.6mm2 Total:233mm2)
Certification : 3C; ISO 9001:2015, ISO 14001:2005, OHSAS 18001:2007
Place of Origin : Henan, China
MOQ : 300 meters
Payment Terms : L/C, T/T,
Delivery Time : 15 days
Packaging Details : Wooden drum, wood and steel drum,as customer's request
Material : AL & STEEL
Core : Customized
Cable Drum Length : Customized
Armoured : No
Total Area : 18.7~1211
Overhead Bare Conductor Wire(Area AL:200mm2 Steel:32.6mm2 Total:233mm2), ACSR Conductor according to IEC 61089
Overhead Bare Conductor Wire APPLICATION
ACSR conductors are widely used for electrical power transmission over long distances, since they are ideal for long overhead lines spans. They are also used as a messenger for supporting overhead electrical cables.
Overhead Bare Conductor Wire CONSTRUCTION
ACSR conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The wire or wires which form the core, are made of galvanized steel and the external layer or layers, are of aluminium. Galvanized steel core consist normally of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different.
By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U. T. S. Can be obtained, by increasing steel content, and a higher current carrying capacity by increasing aluminium content.
Overhead Bare Conductor Wire ELECTRICAL PROPERTIES
| density@20ºC | Aluminium: 2.703 kg/dm | 
| Galvanised Steel: 7.80 kg/dm | |
| Temperature Coefficient@20°C | Aluminium: 0.00403 (°C) | 
| resistivity@20°C | Aluminium: Should not exceed 0.028264 | 
| linear Expansivity 
 | Aluminium: 23 x10 (°C) | 
| Galvanised Steel: 11.5 x10 (1/°C) | 
SERVICE CONDITIONS
| Ambient Temperature | -5°C - 50°C | 
| Wind Pressure | 80 – 130kg/m | 
| Seismic Acceleration | 0.12 - 0.05g | 
| Isokeraunic level | 10 – 18 | 
| relative Humidity | 5 – 100% | 
TECHNICAL DATA
| Numbers of Wires | Modules of Elasticity | Coeficient of linear Expansion | |||
| AL | STEEL | Kg/mm2 | Lb/in2 | 1/Cº | 1/Fº | 
| 6 | 1 | 81 | 11.5 x106 | 19.1 x10-6 | 10.6 x10-6 | 
| 6 | 7 | 77 | 11.0 x106 | 19.8 x10-6 | 11.0 x10-6 | 
| 12 | 7 | 107 | 15.2 x106 | 15.3 x10-6 | 8.5 x10-6 | 
| 18 | 1 | 67 | 9.5 x106 | 21.2 x10-6 | 11.8 x10-6 | 
| 24 | 7 | 74 | 10.5 x106 | 19.6 x10-6 | 10.9 x10-6 | 
| 26 | 7 | 77 | 10.9 x106 | 18.9 x10-6 | 10.5 x10-6 | 
| 28 | 7 | 79 | 11.2 x106 | 18.4 x10-6 | 10.2 x10-6 | 
| 30 | 7 | 82 | 11.6 x106 | 17.8 x10-6 | 9.9 x10-6 | 
| 30 | 19 | 80 | 11.4 x106 | 18.0 x10-6 | 10.0 x10-6 | 
| 32 | 19 | 82 | 11.7 x106 | 17.5 x10-6 | 9.7 x10-6 | 
| 54 | 7 | 70 | 9.9 x106 | 19.3 x10-6 | 10.7 x10-6 | 
| 54 | 19 | 68 | 9.7 x106 | 19.4 x10-6 | 10.8 x10-6 | 
CONSTRUCTION PARAMETERS
• IEC 60189
| Code | Nominal Area | Stranding | Overall Diameter | Weight | Breaking Load | Electrical Resistance @20° | Current Rating* | |||
| AL | STEEL | TOTAL | AL | STEEL | ||||||
| mm2 | mm2 | mm2 | No.xmm | No.xmm | mm | Kg/Km | KN | Ω/Km | A | |
| 16 | 16 | 2.67 | 18.7 | 6/1.84 | 1/1.84 | 5.52 | 64.6 | 6.08 | 1.7934 | 85 | 
| 25 | 25 | 4.17 | 29.2 | 6/2.30 | 1/2.30 | 6.9 | 100.9 | 9.13 | 1.1478 | 112 | 
| 40 | 40 | 6.67 | 46.7 | 6/2.91 | 1/2.91 | 8.73 | 161.5 | 14.4 | 0.7174 | 150 | 
| 63 | 63 | 10.5 | 73.5 | 6/3.66 | 1/3.66 | 10.98 | 254.4 | 21.63 | 0.4555 | 198 | 
| 100 | 100 | 16.7 | 117 | 6/4.61 | 1/4.61 | 13.83 | 403.8 | 34.33 | 0.2869 | 263 | 
| 125 | 125 | 6.94 | 132 | 18/2.97 | 1/2.97 | 14.85 | 397.9 | 29.17 | 0.2304 | 299 | 
| 125 | 125 | 20.4 | 145 | 26/2.47 | 7/1.92 | 15.64 | 503.9 | 45.69 | 0.231 | 302 | 
| 160 | 160 | 8.89 | 169 | 18/3.36 | 1/3.36 | 16.8 | 509.3 | 36.18 | 0.18 | 347 | 
| 160 | 160 | 26.1 | 186 | 26/2.80 | 7/2.18 | 17.74 | 644.9 | 57.69 | 0.1805 | 351 | 
| 200 | 200 | 11.1 | 211 | 18/3.76 | 1/3.76 | 18.8 | 636.7 | 44.22 | 0.144 | 398 | 
| 200 | 200 | 32.6 | 233 | 26/3.13 | 7/2.43 | 19.81 | 806.2 | 70.13 | 0.1444 | 402 | 
| 250 | 250 | 24.6 | 275 | 22/3.80 | 7/2.11 | 21.53 | 880.6 | 68.72 | 0.1154 | 458 | 
| 250 | 250 | 40.7 | 291 | 26/3.50 | 7/2.72 | 22.16 | 1007.7 | 87.67 | 0.1155 | 461 | 
| 315 | 315 | 21.8 | 337 | 45/2.99 | 7/1.99 | 23.91 | 1039.6 | 79.03 | 0.0917 | 526 | 
| 315 | 315 | 51.3 | 366 | 26/3.93 | 7/3.05 | 24.87 | 1269.7 | 106.83 | 0.0917 | 530 | 
| 400 | 400 | 27.7 | 428 | 45/3.36 | 7/2.24 | 26.88 | 1320.1 | 98.36 | 0.0722 | 607 | 
| 400 | 400 | 51.9 | 452 | 54/3.07 | 7/3.07 | 27.63 | 1510.3 | 123.04 | 0.0723 | 610 | 
| 450 | 450 | 31.1 | 481 | 45/3.57 | 7/2.38 | 28.56 | 1485.2 | 107.47 | 0.0642 | 651 | 
| 450 | 450 | 58.3 | 508 | 54/3.26 | 7/3.26 | 29.34 | 1699.1 | 138.42 | 0.0643 | 655 | 
| 500 | 500 | 34.6 | 535 | 45/3.76 | 7/2.51 | 30.09 | 1650.2 | 119.41 | 0.0578 | 693 | 
| 500 | 500 | 64.8 | 565 | 54/3.43 | 7/3.43 | 30.87 | 1887.9 | 153.8 | 0.0578 | 697 | 
| 560 | 560 | 38.7 | 599 | 45/3.98 | 7/2.65 | 31.83 | 1848.2 | 133.74 | 0.0516 | 741 | 
| 560* | 560 | 70.9 | 631 | 54/3.63 | 19/2.18 | 32.68 | 2103.4 | 172.59 | 0.0516 | 745 | 
| 630 | 630 | 43.6 | 674 | 45/4.22 | 7/2.81 | 33.75 | 2079.2 | 150.45 | 0.0459 | 794 | 
| 630* | 630 | 79.8 | 710 | 54/3.85 | 19/2.31 | 34.65 | 2366.3 | 191.77 | 0.0459 | 798 | 
| 710 | 710 | 49.1 | 759 | 45/4.48 | 7/2.99 | 35.85 | 2343.2 | 169.56 | 0.0407 | 851 | 
| 710* | 710 | 89.9 | 800 | 54/4.09 | 19/2.45 | 36.79 | 2666.8 | 216.12 | 0.0407 | 856 | 
| 800* | 800 | 34.6 | 835 | 72/3.76 | 7/2.51 | 37.61 | 2480.2 | 167.41 | 0.0361 | 910 | 
| 800* | 800 | 66.7 | 867 | 84/3.48 | 7/3.48 | 38.28 | 2732.7 | 205.33 | 0.0362 | 912 | 
| 800* | 800 | 101 | 901 | 54/4.34 | 19/2.61 | 39.09 | 3004.9 | 243.52 | 0.0362 | 916 | 
| 900* | 900 | 38.9 | 939 | 72/3.99 | 7/2.66 | 39.9 | 2790.2 | 188.33 | 0.0321 | 972 | 
| 900* | 900 | 75 | 975 | 84/3.69 | 7/3.69 | 40.59 | 3074.2 | 226.5 | 0.0322 | 974 | 
| 1000* | 1000 | 43.2 | 1043 | 72/4.21 | 7/2.80 | 42.08 | 3100.3 | 209.26 | 0.0289 | 1031 | 
| 1120* | 1120 | 47.3 | 1167 | 72/4.45 | 19/1.78 | 44.5 | 3464.9 | 234.53 | 0.0258 | 1096 | 
| 1120* | 1120 | 91.2 | 1211 | 84/4.12 | 19/2.47 | 45.31 | 3811.5 | 283.17 | 0.0258 | 1100 | 
| 1250* | 1250 | 102 | 1352 | 84/4.35 | 19/2.61 | 47.85 | 4253.9 | 316.04 | 0.0232 | 1165 | 
| 1250* | 1250 | 52.8 | 1303 | 72/4.70 | 19/1.88 | 47 | 3867.1 | 261.75 | 0.0231 | 1163 | 
| 1120* | 1120 | 91.2 | 1211 | 84/4.12 | 19/2.47 | 45.31 | 3811.5 | 283.17 | 0.0258 | 1100 | 
 
  
Why you choose us?
|   | 
| ACSR Overhead Bare Conductor Wire (Area AL:200mm2 Steel:32.6mm2 Total:233mm2) (AAC,AAAC,ACSR) Images | 
 ACSR Overhead Bare Conductor With Code Is 16~1120 Basic Design To BS 215-2 / BS
                                                                                    
                        
                        
                        
                                                            ACSR Overhead Bare Conductor With Code Is 16~1120 Basic Design To BS 215-2 / BS
                                                    
                        
                     Overhead ACSR Aluminum Conductor Steel Reinforced With 18.7~1211 Total Area
                                                                                    
                        
                        
                        
                                                            Overhead ACSR Aluminum Conductor Steel Reinforced With 18.7~1211 Total Area
                                                    
                        
                     Anti Rust ACSR Moose Conductor / Industry ACSR Lapwing Conductor Wear Resistance
                                                                                    
                        
                        
                        
                                                            Anti Rust ACSR Moose Conductor / Industry ACSR Lapwing Conductor Wear Resistance
                                                    
                        
                     Overhead Bare Conductor Wire/Cable (Area AL:40mm2 Steel:6.67mm2 Total:46.7mm2)
                                                                                        
                                                        
                        
                        
                        
                                                            Overhead Bare Conductor Wire/Cable (Area AL:40mm2 Steel:6.67mm2 Total:46.7mm2)
                                                    
                        
                     BS 215-2 Bare ACSR Dog Conductor / Power Transmission Reinforced Electrical
                                                                                        
                                                        
                        
                        
                        
                                                            BS 215-2 Bare ACSR Dog Conductor / Power Transmission Reinforced Electrical
                                                    
                        
                     Overhead Bare Conductor Wire ( Area AL:160mm2 Steel:26.1mm2 Total 186mm2 ),
                                                                                        
                                                        
                        
                        
                        
                                                            Overhead Bare Conductor Wire ( Area AL:160mm2 Steel:26.1mm2 Total 186mm2 ),
                                                    
                        
                     Bare ACSR Conductor For Code 16~1250 And The Total Area Is: 18.7~1352 Mm2 (AAAC,
                                                                                    
                        
                        
                        
                                                            Bare ACSR Conductor For Code 16~1250 And The Total Area Is: 18.7~1352 Mm2 (AAAC,
                                                    
                        
                     ACSR Bare Aluminium Conductor Steel Reinforced For Overhead Transmission Line
                                                                                        
                                                        
                        
                        
                        
                                                            ACSR Bare Aluminium Conductor Steel Reinforced For Overhead Transmission Line
                                                    
                        
                     Bare Conductor With AL & Steel And Have The Code As :200/250/315/400/450/560/630
                                                                                        
                                                        
                        
                        
                        
                                                            Bare Conductor With AL & Steel And Have The Code As :200/250/315/400/450/560/630
                                                    
                        
                     ACSR Overhead Bare Aluminum Stranded Conductor / Overhead Wire Basic Design To
                                                                                    
                        
                        
                        
                                                            ACSR Overhead Bare Aluminum Stranded Conductor / Overhead Wire Basic Design To